site's network. Perform the following steps:
• Upgrade the Allworx server to System Software Release 6.9.2.1 or
higher.
• Ensure that the server's DHCP server is enabled. This setting is found on
the Allworx server admin page under Servers > DHCP. Note that if the
Allworx server is on a network that already has a separate DHCP server,
the Allworx server must be disconnected from the network before you
enable DHCP on the Allworx server.
• If the Px has already been powered on, disconnect power.
• Connect a standard RJ-45 category 5 Ethernet cable to the Px's
Network port.
• Connect the other end of the cable to the LAN port of the Allworx server,
either directly or through a network switch
• Apply power to the Px.
The Px's Power LED will flash green for up to three minutes. When it stops
flashing and lights solid green, the upgrade is complete. It will now plug
and play with any server running System Software Release 6.9 or higher.
B. Manually configure Px network settings – In this procedure, you will
set up a direct, one-to one connection between a PC and the Px. You will
boot the Px in Configuration Mode and manually configure its Boot Server
IP Address. Subsequently when it is connected to the customer's network,
it will successfully plug and play and automatically upgrade to a version of
software that will be able to use the DHCP Option 66 information. Once
that is done, no further action is necessary. However, it may be desirable
to clear out the manually-set Boot Server IP Address on the Px. Perform
the following steps:
• If the Px has already been powered on, disconnect power.
• If a cable is plugged into the Network port, disconnect it.
• Set up the PC's network interface to obtain an IP address automatically
(using DHCP).
• Apply power to the Px.
• Wait until the power and port LEDs light solid amber (about 45
seconds). Connect the PC's network port to the Px's Network port with a
standard RJ-45 category 5 Ethernet cable.
Comentarios a estos manuales